USA ▼
Products > Noise Signs > SoundEar > SoundEar II

SoundEar II Noise Activated Warning Sign

SoundEar II Noise Warning Sign
SoundEar II Noise Warning Sign
SoundEar II Noise Warning Sign At a Nurses Station and Corridor Noise in Neonatal and NICU

Price List

SE2EAR
$695.00
SoundEar II Noise Warning Sign
In stock
SE2EAR5
$3409.00
Five Noise Warning Signs and one Noise Meter
In stock

SE2EAR10
$6467.00
Ten Noise Warning Signs and one Noise Meter
In stock
SE2VESA
$36.00
Wall and corner mount
In stock

SEEXT
$122.00
Microphone and 2m extension cable
In stock

SEEXTCAB5
$47.00
5m (16ft) Microphone Extension Cable (needs SEEXT)
Lead time 1 week

POWEX10
$17.00
DC power extension cable 10m (32ft)
In stock

P-SE2
$48.00
Power Supply for SoundEar II
In stock

The delivery price is calculated during checkout based on your location and the goods ordered. Our basic delivery prices are:

Delivery within USA: $40.00

Delivery Service: Five working days*

* For products that are in stock and the order received by midday.

Some products go through a final configuration and calibration before being shipped. If the calibration labs are busy this can add up to two days on to the delivery schedule but guarantees a fresh calibration.

SE2EAR
$695.00
SoundEar II Noise Warning Sign
In stock

Features

  • Lights up when noise levels are too high
  • Attractive design for use in public areas
  • Green = Monitoring : Yellow = Getting loud : Red = Too loud
  • Warning level adjustable from 40 to 115 dB(A)
  • Outdoor version available

Applications

  • Hospital noise
  • NICU and neonatal units
  • Schools - study rooms, classrooms, cafeteria, library
  • Offices and Call Centers
  • Entertainment Venues
  • Noise at Work - see SoundEar II Industrial

Overview

The SoundEar II mounts on the wall and can be set to light up when the noise levels are too high. Unlike many noise monitoring products the SoundEar has been specifically designed to look good. This is clearly important when the unit is to be mounted in a public place.

noise warning in an office

The "you are being too loud" message that the SoundEar provides is unmistakable to both children and adults, allowing them to take immediate action without the embarrassment of somebody having to ask them to be quiet.

Often the biggest issue is with loud voices. A reminder from a sign is better than from another person as it takes away the human perception of noise (maybe the complainer is being a little over sensitive sometimes). It removes the embarrassment from the complainer and from the noisy person.

Setting the Noise Limit

Different areas need more quiet than others. A hospital recovery room needs to be very quiet, whereas a waiting room is not so critical, as long as visitors are not talking too loud or shouting. A school classroom should be reasonably quiet, but the cafeteria a little louder.

The sound level at which the lights come on is set using a dial that is hidden on the back of the sign.

Where SoundEar Helps

The SoundEar Noise Warning Sign can help where people need to be reminded to keep their noise levels down. For example, in hospitals the noise comes from patients, staff and of course from visitors. The presence of the sign is usually enough to remind people that noise is an issue. The yellow and red lights are for those who forget or who are unable to judge what "too loud" is.

The types of noise that will usually trigger the SoundEar are:

  • Loud voices, shouting, whistling
  • Hospital equipment carts (especially if badly maintained)
  • Banging doors
  • Loud music or televisions

Noise in Hospitals

Controlling sound levels in hospital corridors, rooms and nurses stations. Just the presence of the sign is often reminder enough to a successful noise control program.

The SoundEar Noise Warning Sign has proved very popular in hospitals, reminding staff, patients and visitors to be quiet in the usual locations:

  • Nurses' station
  • Corridors close to treatment rooms
  • Noise on hospital units
  • Room entrances and exits

These signs are commonly used within NICU and neonatal units, as well as on other general and intensive care units to remind not just the visitors but also the staff and patients to keep their noise levels down.

The presence of the noise warning sign in an obvious location is often enough to remind people about the area's sensitivity to noise.

Why a Noise Warning Sign

Other than important alarms, there is usually no need for excessive noise on a hospital unit. It is usually caused by visitors and sometimes staff talking louder than necessary or people being careless when moving medical equipment or patients between rooms.

The SoundEar II is a clear and simple reminder to keep the noise levels down and if you forget it lights up to remind you.

Using the Noise Warning Sign in a Hospital

The perfect location for a sign depends on the layout and the acoustics of the area in question. The most important aspect of the SoundEar is that it reminds people to keep the level down, so it is best to mount them where clearly visible to anybody entering the room or area. Often the Nurses Station is a good place to position one unit as this is usually in view to any body visiting and also to constantly remind the staff.

There is no simple rule about the level at which the sign should light up. Hospital units and areas have different ambient noise levels and different acceptable limits. An intensive care unit will have a much lower noise threshold than a busy area dealing with less critical illnesses. The best way to find the comfortable limit for an area it to set the sign up to 55 dB (using the dial on the back). Run the sign for a few hours, or even a few days, and get a feel for whether it is being too sensitive for the given environment or whether it is letting people get away with too much. Adjust up or down by 5 dB as needed.

A level of 45 to 55 dB is common for neonatal and intensive care units and 50 to 60 dB is common for other areas, although it does depend a lot on the acoustics of the areas in question.

Noise in Neonatal and NICU

  • Remind staff and visitors to keep their noise down
  • Reduce the harmful influence of high noise levels
  • Helps to reduce stress levels in infants
  • Unbiased view of the actual noise level

Hospitals with concern about the noise levels in neonatal, intensive care and children's units are our biggest customers for the noise warning sign. Babies in intensive care are particularly sensitive to high noise levels and to the increased stress that they cause.

Noise from visitors and staff is best dealt with using a device such as the SoundEar as it is not influenced by the complicated human perception of noise.

Neonatal units, like most hospital environments, tend to be very poor acoustically due to hard, reflective surfaces. Beds are often closely spaced, visitors can talk loudly (especially the younger ones) and staff have to work quickly and move equipment about. Add to this the incubators being opened and closed, occasional tapping on the lid and items dropped accidentally and the noise levels soon become unpleasant for the baby. One of the biggest culprits is the alarm, which is clearly essential, but as the background noise levels get higher the alarm has to be louder still. A quieter background allows for quieter alarms.

Immediate Effects of NICU Noise

The immediate effects of noise in the neonatal unit are reasonably clear. The baby's sleep is easily disturbed and sudden loud noises (bangs on the incubator for example) can have a startling affect on the heart rate and breathing patterns.

High and intermittent noise is also unpleasant and distracting for both staff and parents. Defined "Quiet Times", when noise and light levels are kept down, certainly help and are now used in many units.

Long Term Effects of NICU Noise

The long term effects of noise in the NICU are not so obvious. Hearing impairment as a result of exposure to high noise levels can be expected but research over the last few years has also shown a link with language development. This seems to be related to the fact that a baby that goes full term is only exposed to lower frequency noise (< 250 Hz) during the brain and sensory development stages.

Office and Call Center Noise

High noise levels in offices and call centers is usually the result of staff talking too loudly.

Unlike noise in factories, which is covered by regulations for the protection of hearing, noise in offices does not usually cause such damage. The main problems here are with general irritation and making other communication difficult. Some of these problems can be dealt with to some extent by ensuring the room acoustics are good, or even using a noise masking system, such as white noise generators.

Reducing the noise at source us usually the best approach. A manager can ask people to quiet down, but this can cause embarrassment and bad feeling, and also depends on the manager's perception.

office noise

Reducing Noise

These office noise problems are best dealt with using a SoundEar Noise Warning Sign. Mounted on the wall at key positions, the SoundEar's mere presence will remind people to keep their voices down to a reasonable level. Should they forget, it lights up as a reminder, giving a very clear message.

Noise in Schools, Libraries and Cafeterias

Good communications is clearly extremely important in a classroom, so high noise levels are not desirable. After (trying to) keep quiet in a classroom for much of the morning, the cafeteria can seem like a good place to release some energy, although not all present will agree. And finally, a gentle reminder to keep voices low in a library can take away the need to verbally remind people where they are.

Mounting a SoundEar Noise Sign in a prominent position in the class room, cafeteria and library will give a clear reminder. The noise level at which the sign lights up can be set accordingly: low sound level for the library, slightly higher for the classroom and a little more forgiving in the cafeteria.

Use and Mounting

  • Wall mounted warning of high noise levels
  • Remind pupils to be quiet in class
  • Keep sound levels acceptable in the cafeteria
  • Keep voices low in the library

The SoundEar II mounts on the wall on a single screw - see our Installation page for more details. It comes complete with a power adapter, which provides the safe low voltage that the noise sign requires.

Music Noise Monitoring

noise in clubs

Music from pubs, clubs, discos and even restaurants and hotels can cause problems for local residents and be at dangerous levels for staff. The SoundEar II Noise Sign is the perfect solution to keeping control of the noise and monitoring the effectiveness of controls.

  • Pub, club, disco, nightclub and restaurant noise monitoring
  • Protect bar and club staff from dangerous noise levels
  • Avoid noise complaints from residents
  • Inform DJ or live band when the levels are too high

The SoundEar II Noise Warning Sign can be set to light first the yellow and then the red lights when the noise level is above the set limit.

One of the major problems of controlling noise levels in clubs is that of human perception. If the music is to somebody's taste it will not sound so annoying as to whom it is not. On top of this, after just a short time being exposed to high levels the ear becomes less sensitive so it is very difficult to decide whether the level is too high without the use of a noise level measuring device such as the SoundEar.

The SoundEar is mounted on the wall using a single screw and plugs into the power using the adapter provided. It is very quick and easy to install.

Evidence of Compliance - Data Logging SoundEar 3

The data logging version of the SoundEar (the SoundEar 3) stores the sound levels, giving evidence of compliance (or non-compliance). If you need to see how the sound levels have been in your absence then this is the ideal option.

The measurements can be downloaded to a computer using the software that is included with the SoundEar 3.

Noise Activated Sign Installation

The SoundEar II Noise Activated Warning Sign is very easy to install. A simple three to four point process:

  • Mounts on the wall on a single screw
  • Plug in using supplied adapter
  • Set the level at which to light up
  • Adjust the level after a day or two experience

The mounting point can be seen on the rear of the noise sign. A single screw in the wall is adequate to hold the light-weight sign.

setting up the noise warning sign
Mounting and Adjusting the Noise Activated Sign

VESA Mounting

vesa mount for noise sign
Optional Wall Mount

As shown in the image above, the SoundEar II also has standard 75mm x 75mm VESA mounts - this is the standard for mounting televisions and monitors, so many types of mount are available.

A VESA mount is not included with the SoundEar II. The order code is SE2VESA.

Location and Sound Level

The perfect location for a sign depends on the layout and the acoustics of the area in question. The most important aspect of the SoundEar is that it reminds people to keep the level down, so it is best to mount them where clearly visible to anybody entering the room or area.

There is also no simple rule about the level at which the sign should light up. Different areas have different ambient noise levels and different acceptable limits. When a reasonable background level is required for conversation then a good starting point is to set the noise sign to light up at 55 dB(A) - the yellow lights will come on at 50 dB(A). Run the sign for a few hours, or even a few days, and get a feel for whether it is being too sensitive for the given environment or whether it is letting people get away with too much. Adjust up or down by 5 dB as needed.

Power

The SoundEar II comes complete with a power adapter. This provides the safe low voltage that the noise sign requires.

power adapter
Power Adapter

An optional power adapter is available for use in areas that need high electrical safety, such as hospitals, and has been approved in accordance with IEC 60601-1 (medical electrical equipment).

Options and Ordering Information

The standard noise activated warning sign, order code SE2EAR, comes with everything you need to get started:

  • SoundEar II Noise Activated Warning Sign
  • Power Adapter
  • User Manual

Options include a VESA wall mount, for mounting the sign at an angle or in a corner, and an external microphone on an extension cable that plugs in to the bottom of the SoundEar II sign.

Noise Warning Sign Ordering

Order Code
SE2EARSoundEar II Noise Sign
Wall mounted noise activated warning sign including power adapter and user manual

Options and Accessories

SE2VESAVESA Wall Mount
For angled or corner mounting
SEEXTExternal Microphone
With 2m extension cable
SEEXTCAB5Additional 5m Mic Extension Cable
Requires SEEXT option, mic not included
POWEX10Power extension cable 10m
Working at a distance from power outlet

Packages

These packages consist of a noise warning signs and a basic noise meter. The noise meter (an NM102 Sound Level Meter) can be used when setting up the SoundEar signs and for spot checks.

SE2EAR5Five Noise Warning Signs with a Noise Meter
Package includes five SoundEar Noise Warning Signs along with a hand-held Noise Meter. The overall price is less than buying five individual noise warning signs.
SE2EAR10Ten SoundEar Noise Warning Signs with a Noise Meter
Package includes ten SoundEar Noise Warning Signs along with a hand-held Noise Meter. The overall price is less than buying ten individual noise warning signs.

Technical Specifications

Dimensions265 x 205 x 46 mm
1.5 kg
Electrical24VDC - adapter included
Frequency Range20Hz to 16kHz
Trigger Range40 to 115 dB in 5dB steps
Freq. WeightingA
Time WeightingSlow
Deviation±3dB

Environmental

TemperatureOperation: 0 to 50°C
Storage: -20 to 60°C
Damp & DustIP42
CabinetCabinet: Shockproof acrylic